Sign In | Join Free | My frbiz.com |
|
Brand Name : CITY
Model Number : 5SF
Place of Origin : UK
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 3000/pcs/month
Delivery Time : 3-5work days
Packaging Details : Canned
Price : Negotiable
Nominal Range : 0-2000ppm
Maximum Overload : 5000ppm
Expected Operating Life : Two years in air
Output Signal : 0.10 ± 0.02μA/ppm
Product Description:
5SF AD526-W00 Sulfur Dioxide Electrochemical Gas Sensor 2000ppm 5 Series
Features:
CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. The table below shows the
typical response of 5SF sensors to a number of common cross-interfering gases. The figures are expressed as a
percentage of the primary sensitivity (i.e. sulphur dioxide = 100%).
Gas Response Gas Response
Carbon monoxide: <3 Hydrogen: <3
Hydrogen sulphide: ≈200 Hydrogen chloride: ≈15
Nitric oxide: 0 Ethylene: <50
Nitrogen dioxide: ≈-125 ** For details of other possible cross-interfering gases contact City Technology
Specifications:
Temperature Range | -20°C to +50°C |
Pressure Range | Atmospheric ± 10% |
Pressure Coefficient | 0.004 % signal/mBar |
T90 Response Time | <30 seconds |
Relative Humidity Range | 15 to 90% non-condensing |
Typical Baseline Range | 0 ± 2ppm equivalent |
![]() |
5SF AD526-W00 Sulfur Dioxide Electrochemical Gas Sensor 2000ppm 5 Series Images |